About the Builder - M Squared

Michele Myers, President of M Squared Builders & Designers, Inc. is a seasoned professional with over 20 years of experience in project management, contracting and systems engineering. With a Masters Degree in management and an educational background in construction, building science, environmental science and chemistry, Michele has had a life-long interest in improving the environment. Michele’s personal struggle with severe allergies has been the catalyst for her research. 

Michele’s years of devoted study have resulted in numerous designations and accreditations. In her goal to achieve perfection of healthy home building, Michele builds homes that meet the rigorous standards of the Environmental Protection Agency’s Energy Star Program, Carolina Power & Light’s Ideal Choice Home’s and the American Lung Association’s Health House. 

These respected designations are evidence that Michele Myers is a builder passionate about making an exceptional, healthy difference in the building industry and in the lives of her clients.

Design Philosophy and Application

Incorporated into the M Squared design philosophy are the concepts of eliminating sources of pollutants, improving overall air ventilation and filtration, sealing out outdoor pollutants, controlling moisture and air infiltration and improving energy efficiency. Because our customer's health needs vary, for affordable, new home construction, we have created three levels of healthy home standard interior features, which are Bronze, Silver and Gold. Keeping these philosophies in mind for our customers, it is our vision to become the leader in providing healthy living environments.

M Squared Home Features

Mechanical System Characteristics

  • High efficiency pleated filters 
  • Balanced energy recovery ventilation system 
  • 12.6 SEER air source heat pump 
  • Electric water heater 
  • Every return and supply ducted (no panning), then sealed with mastic 

System Improvements 

  • Waterproof foundation system 
  • Air tight, conditioned crawlspace 
  • Sealed polyethylene ground cover 
  • Combination capillary break and termite shield over foundation wall 
  • Exterior rigid foam air flow retarder system and drainage plane, all seams taped 
  • Interior air barrier system, air tight drywall approach 
  • Significant overhangs designed to reduce cooling load 
  • High performance glazing 
  • Balanced energy recovery ventilation system 

Envelope Characteristics 

  • Floor area: 4,548 
  • Foundation Walls: Insulated block crawlspace walls 
  • Wall system: 2x4 with R-13 blown cellulose insulation, rigid foam sheathing and interior sealed air/vapor barrier
  • Attic/Roof: Truss system with R-30 blown cellulose insulation, cathedral systems incorporate R-38 fiberglass batts 
  • Windows: Spectrally selected, aluminum clad wood casements, double glazed, argon filled with Low-E coating

Material Selection: 

  • No VOC paints and sealants 
  • All-hardwood cabinetry 
  • Central vacuum 
  • Complete coverage of hard surface flooring , no carpet

Measured Leakage Characteristics

  • Total envelope CFM at 50 pascals: 1,489 
  • 0.23 CFM/Square foot of envelope 
  • 3.5 ACH at 50 pascals 
  • Duct system leakage to outside: 41 CFM

   

 
Privacy Policy Web Link Policy Contact Us

Inside EEBA | Houses That Work | Conference & Expo | Bookstore | Institute | Legacy Campaign
Resources | Partners / Alliances | Events Calendar | Media | Related Sites | Get Involved | Site Map | Search | Home

© 2008 Energy and Environmental Building Association
6520 Edenvale Boulevard, Suite 112, Eden Prairie, MN 55346
952.881.1098  fax: 952.881.3048  inquiry@eeba.org